
Certifications & ANSI/ESD S20.20 Standards
An ESD floor is only effective when its electrical performance is verified against recognised industry standards. esdflooring.in installs conductive and static dissipative flooring systems that are grounded, resistance tested, and documented to help support your facility's electrostatic discharge control programme.
We perform electrical resistance testing, provide compliance documentation, and verify every installation before project handover to ensure your flooring system performs as specified.

ANSI
ESD S20.20 Reference
Verified Performance, Not Just Installation
An ESD floor only performs when it is correctly installed, properly grounded, and electrically verified. Every project is inspected and tested before handover, helping ensure the flooring system delivers reliable static control throughout its service life.

Resistance Verification
Every ESD flooring installation is verified through electrical resistance testing to confirm that the completed floor achieves the specified conductive or static dissipative resistance range.
Grounding & Installation Inspection
Copper grounding systems, conductive layers, and installation quality are inspected throughout the project to ensure reliable long-term ESD performance before handover.
Compliance Documentation
We provide resistance test reports and installation documentation to support your facility's quality records and ESD control programme requirements.
Standards We Follow & Verify
ESD flooring performance is verified through recognised industry standards, electrical resistance testing, and documented installation procedures. Every project is tested to ensure the specified resistance range is achieved before handover.
ANSI/ESD S20.20
Industry Reference Standard
Our ESD flooring installations are designed to support facilities implementing ANSI/ESD S20.20 electrostatic discharge control programs through proper grounding, installation, and resistance verification.
Conductive Flooring
Resistance Range
Conductive flooring systems are tested to achieve resistance values between 1.0 × 10⁴ Ω and 1.0 × 10⁶ Ω, depending on the project specification.
Static Dissipative Flooring
Resistance Range
Static dissipative flooring systems are tested to achieve resistance values between 1.0 × 10⁶ Ω and 1.0 × 10⁹ Ω as required for controlled ESD environments.
Resistance Testing
Calibrated Test Equipment
Every completed flooring installation can be verified through point-to-point and resistance-to-ground testing using calibrated ESD test instruments.
Compliance Documentation
Project Records
Resistance test reports, grounding verification, and project documentation are provided to support your facility's quality and compliance records.
Installation Verification
Quality Assurance
Each project undergoes installation inspection, grounding verification, and electrical performance testing before final handover.
Technical & Compliance Documents
Every ESD flooring project can be supported with technical documentation to assist facility audits, quality assurance, and ESD control programmes. Documentation is provided according to the project scope and client requirements.
Available Documentation
Provided based on project requirements
ANSI/ESD S20.20 & Compliance FAQs
Find answers to common questions about ANSI/ESD S20.20, resistance testing, grounding requirements, compliance documentation, and ESD flooring systems.
ANSI/ESD S20.20 is the internationally recognized standard for establishing an Electrostatic Discharge (ESD) control program. It defines how flooring, footwear, personnel grounding, workstations, and other ESD control elements work together to protect sensitive electronic components from electrostatic damage.
No. An ESD floor is only one part of a complete ESD control programme. Compliance also depends on proper grounding, footwear systems, workstations, testing procedures, and documented ESD control practices throughout the facility.
Depending on project specifications, we test conductive flooring systems within the range of 1.0 × 10⁴ Ω to 1.0 × 10⁶ Ω and static dissipative flooring systems within the range of 1.0 × 10⁶ Ω to 1.0 × 10⁹ Ω. Final project requirements are always confirmed with the client before installation.
Yes. Every ESD flooring installation includes electrical resistance testing using appropriate test methods. Test reports and project documentation can be provided as part of the project handover where required.
Yes. Our specialists evaluate your industry, production environment, equipment sensitivity, traffic conditions, and required resistance range before recommending the most suitable conductive or static dissipative flooring solution.
Depending on the project scope, we can provide technical datasheets, resistance test reports, installation records, maintenance recommendations, and other supporting documentation required for your ESD control programme.
Need ANSI/ESD S20.20
Documentation or Technical Guidance?
Whether you're designing a new ESD-protected area or upgrading an existing facility, our specialists can recommend the appropriate flooring system, grounding method, resistance range, and provide the documentation needed to support your ESD control programme.
Request Compliance Support
Speak with our ESD flooring specialists.
Compliance Documentation
Technical datasheets, resistance reports and project documentation.
Technical Consultation
Assistance selecting the correct ESD flooring system for your facility.
